CSIO-1600M Serial I/O
CSIO-1600M Serial I/O
Serial port relay
1. 16 relay outputs
2. RS485/RS232, modbus protocol
3. DC9-28V without shipping cost
Prompt: After submitting the Sample Request, the sales will contact you in time
Share
Serial Relay
16 Channel Serial Port Control Module
16 relay control outputs, contact isolation, 10A,Each channel has three terminals, normal open + normal close
Support RS232 and isolate RS485 communication interface;Standard Modbus, supporting Modbus RTU.
Provide param setting software tool;Support for secondary development.
Product Specification Parameters
Parameter
Contact Capacity
Terminal
Data Interface
Rated Voltage/Current
Indication
Weight/Size
Operation Temperature
Default Communication Format
Baud
Illustrate
10A@30VDC,10A@250VAC/100000 Times @10A durability
3 terminals for each channel
solate RS485+RS232
DC9-28V/7.5WMAX
1 Red LED (Power Supply)/1 Red LED(Working)16-Way Red LED(Relay ON/OFF)
0.45KG(net)/200X110X60MM
40°C-85°C
9600/N/8/1Modbus
300-38400bps
Why Chooseus?Find CSIO For Remote ControlHigh Quality And Reliability At The Same Cost
Built In WatchdogFor No Downtime
Supports Reverse PowerConnection
DC9-28V power supplyBuiltin protection for surge,EFT,ESD
The Processor AdoptsA 5V Microcontroller
Fully lsolatedRS485Communication
AWT REVERSE CONNECTO
Strong anti-interference perfor.mance with power supply andsignal isolationpower
supply
Standard Modbus Protocol
Can Set 253 Device Addresses
Support hardware address switch(in board)Support seting address via configtool
Compatible with almost Industrial Utilities, KingView, PLCs, touch screens.
CS-IO Series Selection Table
Model
Relay
Analog
Input
Digital
Input
Serial Port
CS-I0101RS485RS48524CCS-10404DA4CS-10404A426oe16
CS-10204D
RS485
CS-IO222A
lsolate RS485
lsolate RS485
CS-10606D
Isolate RS485
CS-10808D
solate RS485+RS232
CS-101600DI
Isolate RS485+RS232
Notes
Addr Switch(Builtln)
Addr Switch(Builtln)
Addr Switch(BuiltIn)
Addr Switch
Addr Switch
Addr Switch
DIInput Only
CS-O1600M
CS-103200
CS-I01616
16
16
16
Isolate RS485+RS232
Isolate RS485+RS232
solate RS485+RS232
Addr Switch(Builtln)
Addr Switch(BuiltIn)
Addr Switch(Builtln)
Work Modes
Enable You To Navigate Various AutomationScenarios With ease
lf you have customized requirements, please feel free to inquire
NORMAL MODE
The upper computer controls the closure or disconnection, and the relay immediately responds.
FLASHING OPEN AND CLOSING
Flash On/off
Send Command To The Relay, Tthe Relay Wil On for A Periad of Time.
Then Automatically Off, Wice vera.
ACTUAL-SETNUMBERS“O.IUNT:SECOND
Controlloadeara o
ddnnnot
de Pon
LOCAL IN-OUT LINKAGE
Pelay Cutput tishe fetior kased On inputl abe f ollawing C State fecerinl)
mombar
Switcing input
Control load erpaatodicomrocio
LROnd
REMOTE IN-OUT LINKAGE
Iwo Dovise Are wed Totether And Tho put1 o DcaCan motelyCoera Th CDwcg
Output Wiring DiagramBoth Normally Open And Normally Closed SwitchesAre Supported To Meet Various Output ControlRequirements
Low Load Wiring
Applicable when non resistive load current is less than 3A orresistive load current is less than 5A
Equipment size
CS-I01600M Size:200*110*60 Unit: mm Standard Din 35mm Card Track
Durable all series EMC certified lead-free with 3-3/CE certification
Customized development+professional technical support
Widely Used In Various Industries
Greenhouse farmland
Smart Home
Livestock and aquaculture
Access controland security
Intelligent parking
Pump valve control
Smart building
Digital meter
Work Modes
Enable You To Navigate Various AutomationScenarios With ease
In this mode, if the relay is not operated once, it will remain in a state of recovery for acertain period of time after flipping over
Jog command
Supports multiple simultaneous jogs
ControlOutput
Upper Computer
Flash mode: If the relay is not operated once, it will close for a certain period of time andthen automatically disconnectFlashing mode: lf the relay is not operated once, it will open for a certain period of timeand then close itself
Actual time=set number * 0.1, in seconds
LOCAL LINKAGE
In this mode, the control output makes corresponding actions based on the switchinput (linkage or state flip once)
Electric Light
Network interface
WIFI
Solenoid Valve
Upper Computer
Controller
Electrical Machinery
Other Equipment
Switch input quantity
NPN/Dry Contact
Self reset/hold switch/sensor
DUAL MACHINE LINKAGE MODE
in this mode, two devices are paired to achieve interactive linkage control where the triggerand control points of the switch are not together, supporting (hold/self reset) switches andswitch sensors (NPN type)
Network intertace/WIFI
The distance between A and B is relatively long
A-point controloutput
Feedback input ofswitch value at point B
Smart Home SolutionsThe controlinputis transmitted to thecontrolterminal through the networkport/4G using theMODBUS-RTU protocol to controlthe device
Parking Lot SolutionsThe controlinput is transmitted to the controlterminal through the network port/4G using theMODBUS-RTU protocol to control the device
Exhibition Hall Sports Ground SolutionThe controlinput is transmitted to the controlterminal through the network port/4G using theMODBUS-RTU protocol to control the device
Jinan Haiyi lntelligent Technology Co., Ltd. is located inJinan, Shandong Province, focusing on the research, devel-opment, production, and sales of network controllers. Theproducts are CE certified and provide solutions and relatedproducts for large well-known enterprises such as the Chi-nese Academy of Sciences, CRRC, Youren Internet, Huawei,Xijiade, etc.
Main products: CS-l0 series 1-32 serial port l/0 modulesHY-N series gateway controller, cloud solutions.