Skip to product information
1 of 2

CSIO-204 Serial I/O

CSIO-204 Serial I/O

Serial port relay

1. 2 relays and 4 switch inputs

2. RS485, modbus protocol

3DC9-28V without shipping cost

Size

Sample Request

Prompt: After submitting the Sample Request, the sales will contact you in time

Serial Relay 2 Channel Serial Control Module 2 relay outputs, contact isolation, 10A, 3 terminals for each channel4 input with dry contact Support RS485 communication interface;Standard Modbus, supporting Modbus RTU Provide supporting control software;Support for secondary development. Product Specification Parameters Parameter Output Input Data lnterface Rated Voltage/Power Indication Weight/Size Illustrate 2 Relay 10A/30VDC 10A/250VAC/100000 times 4 Input /Dry input RS485 DC9-28V/<1.2W 1 Red LED (Power Supply ) Red LED (Working)2-Way LED(relay) 0.08KG(NET)/97X50X32MM Weight/Size Operation Temperature Default Communication Format Baud 0.08KG(NET)/97X50X32MM -40°C-85°C 9600/N/8/1 300-38400bps Why Chooseus?Find CSIOFor Remote ControlHigh Quality And Reliability At The Same Cost Built In WatchdogFor No Downtime Supports Reverse PowerConnection DC9-28V power supply ANTT REVERSE CONNECTION Standard Modbus Protocol The Processor AdoptsA 5V Microcontroller RS485Communication Strong anti-interference perfor- mance with power supply and signal isolationpower supply Can Set 253 Device Addresses Address allocation through hardware dialing or software Compatible with Force Control, KingView, various models of PLCs, touch screens. Work ModesEnable You To Navigate Various AutomationScenarios With ease If you have customized requirements, please feel free to inquire NORMAL MODE if You Have Customized Requirements, Please Feel Free To Inquire FLASHING OPEN AND CLOSING Flash On/off Send Command To The Relay, The elay Will On f or A Period of Time.Then Automatica by or.wice Versa ACTUAL-SET NUMBERSO.1,UNIT:SECOND Socond sntting forwhing of and flauhing cn mo Camtrallaadenetgieatiom oedrrornecton dolay timo Upper Machine Potit lo n oad LOCALIN-OUT LINKAGE Relary Cutput Make Actions Bared On nput Stafle Follwing Or State Reoersal) SolfLockinqp eti t menker Switching ingput Contrel Lend erernratioordlcannocton 1oac REMOTE IN-OUT LINKAGE Two Dice Are Used Taget her And The input1 of Davicea Can remetely carrol The Relzy? Dewce Output Wiring DiagramBoth Normally Open And Normally Closed SwitchesAre Supported To Meet Various Output ControlRequirements Low Load Wiring Applicable when non resistive load current is less than 3A orresistive load current is less than 5A Input Wiring DiagramBoth Support Dry&Wet Node lutput CSIO-204 connected to active switch (wet or dry contact) Equipment size CS-I0222A Size:81*50*32 Unit: mm Durable all series EMC certified lead-free with 3-3/CE certification Customized development+professional technical support Widely Used In Various Industries Greenhouse farmland Smart Home Livestock and aquaculture Access controland security Intelligent parking Pump valve control Smart building Digital meter Work Modes Enable You To Navigate Various AutomationScenarios With ease In this mode, if the relay is not operated once, it will remain in a state of recovery for acertain period of time after flipping over Jog command Supports multiple simultaneous jogs ControlOutput Upper Computer Flash mode: If the relay is not operated once, it will close for a certain period of time andthen automatically disconnectFlashing mode: lf the relay is not operated once, it will open for a certain period of timeand then close itself Actual time=set number * 0.1, in seconds LOCAL LINKAGE In this mode, the control output makes corresponding actions based on the switchinput (linkage or state flip once) Electric Light Network interface WIFI Solenoid Valve Upper Computer Controller Electrical Machinery Other Equipment Switch input quantity NPN/Dry Contact Self reset/hold switch/sensor DUAL MACHINE LINKAGE MODE in this mode, two devices are paired to achieve interactive linkage control where the triggerand control points of the switch are not together, supporting (hold/self reset) switches andswitch sensors (NPN type) Network intertace/WIFI The distance between A and B is relatively long A-point controloutput Feedback input ofswitch value at point B Smart Home SolutionsThe controlinputis transmitted to
View full details

Contact form

Thank You !
Prompt: After submitting the Sample Request, the sales will contact you in time