Skip to product information
1 of 2

CSIO-1616-ETH4G Remote I/O

CSIO-1616-ETH4G Remote I/O

16 Port Remote I/O Module

1. 16DO+16DI,  4G+RJ45, RS485/RS232

2. DC9-28V, including antenna/network cable

3. RS485+4G+Ethernet interface, MQTT/JSON/Mdobus Protocol

4. Analog quantity interface default 4-20mA


Size

Sample Request

Prompt: After submitting the Sample Request, the sales will contact you in time

Serial Relay CSIO-1616 16DO+16DI Industrial Grade Standard Modbus Communication 16 relay control outputs, contact isolation, 10A;16 inputs with optocoupler, wet/dry nodes suported Support RS232 and isolate RS485 communication interface;Standard Modbus, supporting Modbus RTU. Provide param setting software tool;Support for secondary development. Product Specification Parameters Parameter Output Input Data Interface Rated Voltage/Current Indication Weight/Size Operation Temperature Default Communication Format Baud Illustrate 16 relays 10A@30VDC,10A@250VAC/normally off16 inputs with optical isolation/dry or wet input Isolate RS485+RS232 DC9-28V/7.5WMAX 1 Red LED (Power Supply)/1 Red LED (Working)16-Way Red LED(Relay ON/OFF) 0.45KG(net)/220X113X60MM -40°C-85°C 9600/N/8/1Modbus 300-38400bps Why Choose us?Find CSIO For Remote Control High Quality And Reliability At The Same Cost Built In WatchdogFor No Downtime Supports Reverse PowerConnection DC9-28V power supply Builtin protection for surge,EFT,ESD The Processor AdoptsA 5V Microcontroller m sevdek coieis Fully IsolatedRS485CommunicationStrong anti-interference performance with power supply andsignal isolatjonpower supply Standard Modbus Protocol Can Set 253 Device Addresses Support hardware address switch(in board)Support seting address via configtool Compatible with almost Industrial Utilities, KingView, PLCs, touch screens. CS-IO Series Selection Table Model CS-I0101 CS-10204D CS-I0222A CS-10404D CS-10404A CS-10606D CS-10808D CS-101600DI CS-O1600M Cs-103200 CS-101616 Relay 8 16 16 Analog Input 4 Digital Input Serial Port RS485 4 C RS485 RS485 Isolate RS485 Isolate RS485 lsolate RS485 solate RS485+RS232 16 Isolate RS485+RS232 solate RS485+RS232 solate RS485+RS232 16solate RS485+RS232 Notes Addr Switch(Builtln) Addr Switch(BuiltIn) Addr Switch(BuiltIn) Addr Switch Addr Switch Addr Switch DI Input Only Addr Switch(Builtln) Addr Switch(Builtln) Work ModesEnable You To Navigate Various AutomationScenarios With ease If you have customized requirements, please feel free to inquire NORMAL MODE The upper computer controls the closure or disconnection, and the relay immediately responds. Output Wiring DiagramBoth Normally Open And Normally Closed SwitchesAre Supported To Meet Various Output ControlRequirements Low Load Wiring Applicable when non resistive load current is less than 3A orresistive load currentt is less than 5A Equipment size CS-I01616 Size:200*110*60 Unit: mm Standard Din 35mm Card Track Durable all series EMC certified lead-free with 3-3/CE certification Customized development+professional technical support Widely Used In Various Industries Greenhouse farmland Smart Home Livestock and aquaculture Access controland security Intelligent parking Pump valve control Smart building Digital meter Work Modes Enable You To Navigate Various AutomationScenarios With ease In this mode, if the relay is not operated once, it will remain in a state of recovery for acertain period of time after flipping over Jog command Supports multiple simultaneous jogs ControlOutput Upper Computer Flash mode: If the relay is not operated once, it will close for a certain period of time andthen automatically disconnectFlashing mode: lf the relay is not operated once, it will open for a certain period of timeand then close itself Actual time=set number * 0.1, in seconds LOCAL LINKAGE In this mode, the control output makes corresponding actions based on the switchinput (linkage or state flip once) Electric Light Network interface WIFI Solenoid Valve Upper Computer Controller Electrical Machinery Other Equipment Switch input quantity NPN/Dry Contact Self reset/hold switch/sensor DUAL MACHINE LINKAGE MODE in this mode, two devices are paired to achieve interactive linkage control where the triggerand control points of the switch are not together, supporting (hold/self reset) switches andswitch sensors (NPN type) Network intertace/WIFI The distance between A and B is relatively long A-point controloutput Feedback input ofswitch value at point B Smart Home SolutionsThe controlinputis transmitted to
View full details

Equipment size

Contact form

Thank You !
Prompt: After submitting the Sample Request, the sales will contact you in time