CSIO-101 Serial I/O

CSIO-101 Serial I/O

Serial port relay 

1. 1 relay + 1 optocoupler input

2. 1 RS485, modbus protocol

3DC9-28V power supply

Size

Sample Request

PromptAfter submitting the Sample Request, the sales will contact you in time

Serial Relay 1 Channel Serial Control Module 1 relay outputs, contact isolation, 10A, 3 terminals for each channel1 input with optical isolation Support RS485 communication interface;Standard Modbus, supporting Modbus RTU. Provide supporting control software;Support for secondary development. Product Specification Parameters Parameter Output Input Data Interface Rated Voltage/Power Indication Weight/Size Operation Temperature Default Communication Format Baud Illustrate 1Relay 10A/30VDC 10A/250VAC/100000 times 1 Input with Optical isolation/Dry or wet input RS485 DC9-28V/<0.8W 1 Red LED (Power Supply )1 Red LED (Working)1-Way LED(relay) 0.07KG(NET)/101X50X32MM(With Connector) -40C-85°C 9600/N/8/1 300-38400bps Why ChooseUs?Find CSIOFor Remote ControlHigh Quality And Reliability At The Same Cost Built In WatchdogFor No Downtime Supports Reverse PowerConnection DC9-28V power supply ANTI REVERSE CON NECTION Standard Modbus Protocol The Processor AdoptsA 5V Microcontroller RS485 Communication Strong anti-interference perfor-mance with power supply andsignal isolationpower Supply Can Set 253 Device Addresses Address allocation through hardware dialing or software Compatible with Force Control, KingView, various models of PLCs, touch screens. Work ModesEnable You To Navigate Various AutomationScenarios With ease lf you have customized requirements, please feel free to inquire NORMAL MODE If You Have Customized Requirements, Please Feel Free To Inquire FLASHING OPEN AND CLOSING Flash on/off Send Command To The Pelay, The felay will On for A Period of Time. then Auom saly off, Vice versa. ACTUAL-ETNUNBERS"Q.I,UNISECOND Segnd utting terie ard fusn on Cantrol load enwrgiratiga BNNR LOCAL IN-OUT LINKAGE Relay Output Male ctions llanad Cm lnputs $eate Folowing Or State Recersal) monor switching input AeliLa REMOTE IN-OUT LINKAGE Two Devioe Are Used Tepet her And The ngut1 Of DeviceaCan hem oety Centrel Th Re ayi of Devoe 8 Output Wiring DiagramBoth Normally Open And Normally Closed SwitchesAre Supported To Meet Various Output ControlRequirements Low Load Wiring Applicable when non resistive load current is less than 3A orresistive load current is less than 5A Input Wiring DiagramBoth Support Dry&Wet Node lutput CSIO-101 connectedto active switch(dry or wet contact) have opticalisolation [wet input: can use PNP type switches] Equipment size CS-I0101 Unit: mm Size(Without connector):81*50*32(With connector):102*50*32 Durable all series EMC certified lead-free with 3-3/CE certification Customized development+professional technical support Widely Used In Various Industries Greenhouse farmland Smart Home Livestock and aquaculture Access controland security Intelligent parking Pump valve control Smart building Digital meter Work Modes Enable You To Navigate Various AutomationScenarios With ease In this mode, if the relay is not operated once, it will remain in a state of recovery for acertain period of time after flipping over Jog command Supports multiple simultaneous jogs ControlOutput Upper Computer Flash mode: If the relay is not operated once, it will close for a certain period of time andthen automatically disconnectFlashing mode: lf the relay is not operated once, it will open for a certain period of timeand then close itself Actual time=set number * 0.1, in seconds LOCAL LINKAGE In this mode, the control output makes corresponding actions based on the switchinput (linkage or state flip once) Electric Light Network interface WIFI Solenoid Valve Upper Computer Controller Electrical Machinery Other Equipment Switch input quantity NPN/Dry Contact Self reset/hold switch/sensor DUAL MACHINE LINKAGE MODE in this mode, two devices are paired to achieve interactive linkage control where the triggerand control points of the switch are not together, supporting (hold/self reset) switches andswitch sensors (NPN type) Network intertace/WIFI The distance between A and B is relatively long A-point controloutput Feedback input ofswitch value at point B Smart Home SolutionsThe controlinputis transmitted to thecontrolterminal through the networkport/4G using theMODBUS-RTU protocol to controlthe device Parking Lot SolutionsThe controlinput is transmitted to the controlterminal through the network port/4G using theMODBUS-RTU protocol to control the device Exhibition Hall Sports Ground SolutionThe controlinput is transmitted to the controlterminal through the network port/4G using theMODBUS-RTU protocol to control the device Jinan Haiyi lntelligent Technology Co., Ltd. is located inJinan, Shandong Province, focusing on the research, devel-opment, production, and sales of network controllers. Theproducts are CE certified and provide solutions and relatedproducts for large well-known enterprises such as the Chi-nese Academy of Sciences, CRRC, Youren Internet, Huawei,Xijiade, etc. Main products: CS-l0 series 1-32 serial port l/0 modulesHY-N series gateway controller, cloud solutions.
View full details

Contact form

Thank You !
Prompt: After submitting the Sample Request, the sales will contact you in time