CSIO-101 Serial I/O
CSIO-101 Serial I/O
Serial port relay
1. 1 relay + 1 optocoupler input
2. 1 RS485, modbus protocol
3. DC9-28V power supply
Prompt: After submitting the Sample Request, the sales will contact you in time
Share
Serial Relay
1 Channel Serial Control Module
1 relay outputs, contact isolation, 10A, 3 terminals for each channel1 input with optical isolation
Support RS485 communication interface;Standard Modbus, supporting Modbus RTU.
Provide supporting control software;Support for secondary development.
Product Specification Parameters
Parameter
Output
Input
Data Interface
Rated Voltage/Power
Indication
Weight/Size
Operation Temperature
Default Communication Format
Baud
Illustrate
1Relay 10A/30VDC 10A/250VAC/100000 times
1 Input with Optical isolation/Dry or wet input
RS485
DC9-28V/<0.8W
1 Red LED (Power Supply )1 Red LED (Working)1-Way LED(relay)
0.07KG(NET)/101X50X32MM(With Connector)
-40C-85°C
9600/N/8/1
300-38400bps
Why ChooseUs?Find CSIOFor Remote ControlHigh Quality And Reliability At The Same Cost
Built In WatchdogFor No Downtime
Supports Reverse PowerConnection
DC9-28V power supply
ANTI REVERSE CON NECTION
Standard Modbus Protocol
The Processor AdoptsA 5V Microcontroller
RS485
Communication
Strong anti-interference perfor-mance with power supply andsignal isolationpower
Supply
Can Set 253 Device Addresses
Address allocation through hardware dialing or software
Compatible with Force Control, KingView, various models of PLCs, touch screens.
Work ModesEnable You To Navigate Various AutomationScenarios With ease
lf you have customized requirements, please feel free to inquire
NORMAL MODE
If You Have Customized Requirements, Please Feel Free To Inquire
FLASHING OPEN AND CLOSING
Flash on/off
Send Command To The Pelay, The felay will On for A Period of Time.
then Auom saly off, Vice versa.
ACTUAL-ETNUNBERS"Q.I,UNISECOND
Segnd utting terie ard fusn on
Cantrol load enwrgiratiga
BNNR
LOCAL IN-OUT LINKAGE
Relay Output Male ctions llanad Cm lnputs $eate Folowing Or State Recersal)
monor
switching input
AeliLa
REMOTE IN-OUT LINKAGE
Two Devioe Are Used Tepet her And The ngut1 Of DeviceaCan hem oety Centrel Th Re ayi of Devoe 8
Output Wiring DiagramBoth Normally Open And Normally Closed SwitchesAre Supported To Meet Various Output ControlRequirements
Low Load Wiring
Applicable when non resistive load current is less than 3A orresistive load current is less than 5A
Input Wiring DiagramBoth Support Dry&Wet Node lutput
CSIO-101 connectedto active switch(dry or wet contact)
have opticalisolation
[wet input: can use PNP type switches]
Equipment size
CS-I0101 Unit: mm
Size(Without connector):81*50*32(With connector):102*50*32
Durable all series EMC certified lead-free with 3-3/CE certification
Customized development+professional technical support
Widely Used In Various Industries
Greenhouse farmland
Smart Home
Livestock and aquaculture
Access controland security
Intelligent parking
Pump valve control
Smart building
Digital meter
Work Modes
Enable You To Navigate Various AutomationScenarios With ease
In this mode, if the relay is not operated once, it will remain in a state of recovery for acertain period of time after flipping over
Jog command
Supports multiple simultaneous jogs
ControlOutput
Upper Computer
Flash mode: If the relay is not operated once, it will close for a certain period of time andthen automatically disconnectFlashing mode: lf the relay is not operated once, it will open for a certain period of timeand then close itself
Actual time=set number * 0.1, in seconds
LOCAL LINKAGE
In this mode, the control output makes corresponding actions based on the switchinput (linkage or state flip once)
Electric Light
Network interface
WIFI
Solenoid Valve
Upper Computer
Controller
Electrical Machinery
Other Equipment
Switch input quantity
NPN/Dry Contact
Self reset/hold switch/sensor
DUAL MACHINE LINKAGE MODE
in this mode, two devices are paired to achieve interactive linkage control where the triggerand control points of the switch are not together, supporting (hold/self reset) switches andswitch sensors (NPN type)
Network intertace/WIFI
The distance between A and B is relatively long
A-point controloutput
Feedback input ofswitch value at point B
Smart Home SolutionsThe controlinputis transmitted to thecontrolterminal through the networkport/4G using theMODBUS-RTU protocol to controlthe device
Parking Lot SolutionsThe controlinput is transmitted to the controlterminal through the network port/4G using theMODBUS-RTU protocol to control the device
Exhibition Hall Sports Ground SolutionThe controlinput is transmitted to the controlterminal through the network port/4G using theMODBUS-RTU protocol to control the device
Jinan Haiyi lntelligent Technology Co., Ltd. is located inJinan, Shandong Province, focusing on the research, devel-opment, production, and sales of network controllers. Theproducts are CE certified and provide solutions and relatedproducts for large well-known enterprises such as the Chi-nese Academy of Sciences, CRRC, Youren Internet, Huawei,Xijiade, etc.
Main products: CS-l0 series 1-32 serial port l/0 modulesHY-N series gateway controller, cloud solutions.