BAC2004-ARM
BAC2004-ARM
Bacnet Gateway with 2 ethport & 4 serialport ofRS485/232, CPU 300MHz, 300+ protocols support from data monitor side, such as BACnet modbus mbus mqtt dlt645 Siemens telnet OPCUA SNMP EthernetIP
Prompt: After submitting the Sample Request, the sales will contact you in time
Share
Independently developed configurationsare convenient and stable
Intelligent management, supporting PC, mobile.iPad and other monitoring, with strong operability
Function Description
the function ofX2BACnet is transformstandard protocols and some non-standardcommuncation protocols, to standardBACnetlP protocol.enable users to accesingthe on-site device data by BACnet.
Application Area
The hardware gateway supports converting standard protocols and somenon-standard protocols into The BACnet protocol, like Johnson's Metasys,Horney's EBl, or Niagara, Siemens' lnsight or Desigo cc, Schneider SBO, and otherlarge building automation company's MCGS is unableto connect to some uncommon control equipment issues,Such as PLC, air conditioning, elevators, fire protection, lighting control systems, electricity meters,water meters, etc. Connect standard Modbus protocols and some non-standardModbus protocols through a hardware gateway Convert to BACnet standard protocol, so that the BACnet client software can Access to on-site devices through the gateway.
OperatingEnvironment
The software supports multiple operating systems such as WindowsXP/2000/2003/Win7/Win8/Win10/Win Server 2003/Win Server 2008/Win VistaThe software comes with WEB support for lE9 and above versions, as well asOpera and Apple's Safari, Google Chrome, Firefox browser, etc.
Support Register TypeAnd Number
BAC Net Support Register Types
AI(READ ONLY NOT WRITE)
AO(READ OREADABLE AND WRITABLE)
AV(READ ONLY NOT WRITE)BI(READ OREADABLE AND WRITABLE)
BO(READ ONLY NOT WRITE)BV(READ OREADABLE AND WRITABLE)
MSI(READ ONLY NOT WRITE)MSO(READ OREADABLE AND WRITABLE)
MSV(READ OREADABLE AND WRITABLE)
BAC Net Number of Supported Registers
256 ( 0-256 )
256 ( 0-256 )
256( 0-256 )
256( 0~256 )
256( 0-256 )
256( 0256 )
256 ( 0-256 )
256 ( 0-256 )
256( 0256 )
Software Features
-Green installation free, supporting multiple languages;0-Support the simultaneous conversion of standard protocols and somenon-standard protocols to BACnetIP servers;-Support PC, mobile, iPad, and other access andmonitoring;
-Supports linear conversion, bit taking, and highlow byte conversion;
-Support internal variable function and view deviceoffline status;
-Supports nine register types: Al, AO, AV, Bl, BO, BV, MSI, MSO, and MSV:-The configuration software X2BACnet is easy to configure, and can becompleted in 256 points in 10 minutes;-Add a new private protocol to support BACnet, which can be completedwithin 2 weeks;
Hardware Parameters
Processor: 1 core 300MHZ Power supply: AC 12-24V/DC 12-42VMemory: 64M Flash: 128MSystem: LINUX System power consumption: 6WWeight: 300g Material: galvanized carbon steelInstallation method: guide rail typeSize (L X W X H) : 118mm X 74mm X 35mmInterface: 1 network port, 1 RS485/RS232(multiplexing relationship)Temperature:-20~70 C (working)-40~80C(storage and transportation)o..Network: 1 high-performance 100M/10M EthernetB nxinterface, supporting AUTO MDI/MDIXHumidity: 20% -90% non condensing (working)15% -95% non condensing (storage andtransportation)
Some Protocols are Shown in The Table Below
BACnet IP
Modbus TCP
MBus_EnergyMeter EN
欧洲标准热量表
Otis Elevator BA Interface
奥的斯电梯
Modbus PM800
施耐德电表
EMERSON ACMO3U1
艾默生精密空调
OMRON FINS UDP
欧姆龙FINS UDP系列PLC
KNXnetIP MultiCast
智能照明-组播
NOTIFIRE NFS2 3030 CRT
诺帝菲尔消防报警系统
BACnet MSTP
SNMP
MBus EnergerMeter Mbus
国产热量表
DLT645-1997
多功能电表1997标准
Modbus DAIKIN IRACC
大金空调网关
Hitachi Chiller
日立冷机
LS GM GLOFA Enet韩国LG GLOFA-GM PLC
Lutron Telnet
路创Telnet 协议
METTLER TOLEDO SICS
梅特勒-托利多称重秤
Modbus RTU
OPC XML-DA
MBus WaterMeter Mbus
国产水表
DLT645-2007
多功能电表2007标准
DAIKIN DRCH-R5
大金P板_大金空调监控
Mitsubishi Melsec Q TCP三菱Q系列TCP通讯
Siemens S7-1200 Network西门子1200 PLC
EMERSON HIPULSE
Lumi Gateway
Product Size
118mmx74mmx35mm(LxWxH)
BAC1001-ARMField ApplicationSchematic Diagram
Scenario 1:Integrate network interface protocolusing modbus TCP as an example) to BAS
Scenario 2:Integrating Serial Port Protocol(Using Modbus TCP as an Example) to BAS
BACnet' Client
BA System
BACnetNetWork
odbus TCP--NetWork
BACnet Client
BA System
BACnetNetwork
IT IS RECOMMENDED TO USE THE SAME TYPEOF DEVICE ON EACH BUS TO ENSURE THESAME COMMUNICATION PARAMETERS
Modbu
Slave
PLC
Wodbu
Slave
Lift
Madbu
Slave
Water meterElectricity meter,Energy meter
1 Bus
Thermostat
Modbus
Slave
odbusRTU
Cooler
Modbus
Slave
Widely Used In Various Industries
Greenhouse farmland
Smart Home
Livestock and aquaculture
Access controland security
Intelligent parking
Pump valve control
Smart building
Digital meter
Work Modes
Enable You To Navigate Various AutomationScenarios With ease
In this mode, if the relay is not operated once, it will remain in a state of recovery for acertain period of time after flipping over
Jog command
Supports multiple simultaneous jogs
ControlOutput
Upper Computer
Flash mode: If the relay is not operated once, it will close for a certain period of time andthen automatically disconnectFlashing mode: lf the relay is not operated once, it will open for a certain period of timeand then close itself
Actual time=set number * 0.1, in seconds
LOCAL LINKAGE
In this mode, the control output makes corresponding actions based on the switchinput (linkage or state flip once)
Electric Light
Network interface
WIFI
Solenoid Valve
Upper Computer
Controller
Electrical Machinery
Other Equipment
Switch input quantity
NPN/Dry Contact
Self reset/hold switch/sensor
DUAL MACHINE LINKAGE MODE
in this mode, two devices are paired to achieve interactive linkage control where the triggerand control points of the switch are not together, supporting (hold/self reset) switches andswitch sensors (NPN type)
Network intertace/WIFI
The distance between A and B is relatively long
A-point controloutput
Feedback input ofswitch value at point B
Smart Home SolutionsThe controlinputis transmitted to thecontrolterminal through the networkport/4G using theMODBUS-RTU protocol to controlthe device
Parking Lot SolutionsThe controlinput is transmitted to the controlterminal through the network port/4G using theMODBUS-RTU protocol to control the device
Exhibition Hall Sports Ground SolutionThe controlinput is transmitted to the controlterminal through the network port/4G using theMODBUS-RTU protocol to control the device
Jinan Haiyi lntelligent Technology Co., Ltd. is located inJinan, Shandong Province, focusing on the research, devel-opment, production, and sales of network controllers. Theproducts are CE certified and provide solutions and relatedproducts for large well-known enterprises such as the Chi-nese Academy of Sciences, CRRC, Youren Internet, Huawei,Xijiade, etc.
Main products: CS-l0 series 1-32 serial port l/0 modulesHY-N series gateway controller, cloud solutions.