Skip to product information
1 of 2

CSIO-404 Serial I/O

CSIO-404 Serial I/O

Serial port relay

1. 4 relays and 4 switch inputs

2. RS485, modbus protocol

3DC9-28V without shipping cost

Size

Sample Request

Prompt: After submitting the Sample Request, the sales will contact you in time

Serial Relay 4 Channel Serial Control Module Industrial Grade Standard Modbus Communication 4 relay control outputs, contact isolation, 10A; 3 Connectors for each channel 4 inputs with optical isolation Supportisolate RS485 communication interfaceStandard Modbus, supporting Modbus RTU Provide supporting control software;Support for secondary development Product Specification Parameters Parameter Output Input Data Interface Rated Voltage Indication Weight/Size Operation Temperature Default Communication Format Baud Illustrate 4 Relays,10A/30VDC 10A/250VAC/100000Times 4 Input with optical IsolationRS485 DC9-28V/<2W 1 Red LED(Power)1 Red LED (Working 4 LEDS(Relay) 0.17KG(net)/115X90X45MM -40°C-85°C 9600/N/8/1 300-38400bps Why Chooseus?Find CSIO For Remote ControlHigh Quality And Reliability At The Same Cost Built In WatchdogFor No Downtime Supports Reverse PowerConnection DC9-28V power supply ANTT REVERSE CONNECTIO Standard Modbus Protocol The Processor AdoptsA 5V Microcontroller Fully lsolatedRS485Communication Strong anti-interference perfor-mance with power supply andsignal isolationpower supply Can Set 253 Device Addresses Address allocation through hardware dialing or software. Work ModesEnable You To Navigate Various AutomationScenarios With ease If you have customized requirements, please feel free to inquire NORMAL MODE If You Have Customized Requirements, Please Feel Free To Inquire Output Wiring DiagramBoth Normally Open And Normally Closed SwitchesAre Supported To Meet Various Output ControlRequirements Low Load Wiring Applicable when non resistive load current is less than 3A orresistive load current is less than 5A Input Wiring DiagramBoth Support Dry&Wet Node lutput CSIO-404 connected to active switch(wet contact NPN typel Each path’ s positive pole is binded inside together CSIO-404 connected to passive switch (dry contact) Equipment size CS-I0404 Size:115*90*45 Unit:mm Standard Din 35mm Card Track Durable all series EMC certified lead-free with 3-3/CE certification Customized development+professional technical support Widely Used In Various Industries Greenhouse farmland Smart Home Livestock and aquaculture Access controland security Intelligent parking Pump valve control Smart building Digital meter Work Modes Enable You To Navigate Various AutomationScenarios With ease In this mode, if the relay is not operated once, it will remain in a state of recovery for acertain period of time after flipping over Jog command Supports multiple simultaneous jogs ControlOutput Upper Computer Flash mode: If the relay is not operated once, it will close for a certain period of time andthen automatically disconnectFlashing mode: lf the relay is not operated once, it will open for a certain period of timeand then close itself Actual time=set number * 0.1, in seconds LOCAL LINKAGE In this mode, the control output makes corresponding actions based on the switchinput (linkage or state flip once) Electric Light Network interface WIFI Solenoid Valve Upper Computer Controller Electrical Machinery Other Equipment Switch input quantity NPN/Dry Contact Self reset/hold switch/sensor DUAL MACHINE LINKAGE MODE in this mode, two devices are paired to achieve interactive linkage control where the triggerand control points of the switch are not together, supporting (hold/self reset) switches andswitch sensors (NPN type) Network intertace/WIFI The distance between A and B is relatively long A-point controloutput Feedback input ofswitch value at point B Smart Home SolutionsThe controlinputis transmitted to
View full details

Equipment size

Contact form

Thank You !
Prompt: After submitting the Sample Request, the sales will contact you in time